CE-6000
Module&Pack
Regenerative Charge and Discharge Battery Testing System
High Frequency Isolation 10V~120V
It has the characteristics of high dynamic response speed, high stability precision and multi-channel flexible configuration which also supports pulse test, cycle life test and simulation test. The system has the function of multi-channel input and energy recovery, which can save a lot of electric energy consumed in the process of charging and discharging. Using bidirectional high-frequency DC converter topology and high-performance multi-channel 24 bit AD converter chip, the sampling resolution is higher than that of traditional single range equipment.
Use data to interprete module testing
-
100HzData Acquisition Frequency
-
RS485 CommunicationCANBus
-
>90%Energy Conversion Efficiency
-
Simulation
-
SupportBMS Docking
-
≥0VDischarge Voltage
-
0.02%/0.05%Accuracy
-
100msMin. Pulse Width
-
≤3msResponse Time
-
Parallel Channels
-
-
Lithium batteries for electric vehicles
-
Lithium battery for electric bicycle
-
Lithium battery for power tools
-
Lithium batteries for garden tools
-
Energy storage lithium battery
Model Description
C
Product
T
①T/Empty
E
60
6 Series Module
&Pack
&Pack
04
Number of Channels
X
②D/T/Q/Empty
n
③n/m
□□□V
Maximum Output Voltage
(V)
(V)
□□□A
Maximum Output Current
(A)
(A)
IG
IGBT
B/F
Charge and Discharge Separation/
Discharge voltage below 0V
Discharge voltage below 0V
①T-Accuracy: 0.02%FS;Empty-Default Accuracy: 0.05%FS or 0.1%FS;
②D-Double Range;T-3 Range;Q-4 Range; Empty-Single Range;
③n-100Hz;m-10Hz;
C
①
T
②
E
60
③
04
④
X
⑤
n
⑥
□□□V
⑦
□□□A
⑧
IG
⑨
B/F
⑩
①Product
②T/Empty
③6 Series Module&Pack
④Number of Channels
⑤D/T/Q/Empty
⑥n/m
⑦Maximum Output Voltage (V)
⑧Maximum Output Current (A)
⑨IGBT
⑩Charge and Discharge Separation/
Discharge voltage below 0V
Typical Model
60V20A | 60V30A | 60V50A | 60V60A | 60V100A | 60V120A |
60V400A | 60V240A | 120V50A | 120V100A | 120V200A | 120V400A |
200V50A | 500V100A | 200V200A | 400V200A | 750V500A | 800V600A |
-B (Charge and Discharge Port) / -F (Negative Pressure) Optional Functions |
Software
Essential components
DBC Configuration Function
Discharge to 0V
Constant Current Charge/Discharge Test
Constant Current/Voltage Charge/Discharge test
100ms Pulse Width
CCDC
CCCV
Simulation
dQ/dV微分容量曲线:曲线上出现峰的地方表示充放电曲线有电压平台,不同的峰代表不同的电化学反应。
在诸多的测试应用中,要同时对多个条件进行判断,根据不同的测量结果响应不同的操作;条件工步满足的条件为多出口的编程方式。与(&&)或(||)逻辑运算,“≥”、“≤”、“=” 比较运算;持续时间“t”,可实现特殊测试的控制要求;每个工步支持5个条件工步;支持多个出口,go to 到任意工步,实现更加灵活的流程控制。
支持以电压、电流、时间分段进行数据记录;每1工步可设置3个分段记录条件;每个分段可设置:△T/△V/△I。
BTS Server 通过交换机对外围设备(检测设备、自动压床)的通信控制。
Q的单位为库仑,1库仑=1A*1s=1As(安秒);1Ah=3600As(安秒);工作电压U=充电上限电压-放电下限电压;工作电压可设置,软件自动计算电容容值(C)。
支持以电压、电流、时间分段进行数据记录;每1工步可设置3个分段记录条件;每个分段可设置:△T/△V/△I。
BTS Server 通过交换机对外围设备(检测设备、自动压床)的通信控制。
dQ/dV微分容量曲线:曲线上出现峰的地方表示充放电曲线有电压平台,不同的峰代表不同的电化学反应。
Modularization of Power Unit
1Modular design is convenient to maintain equipment.
2DC and AC modules are used together, DC BUS is independent;
3Copper bar technology makes the equipment interior much cleaner.
System Protection
Power Grid Over/Under-voltage, AC
Short Circuit, Phase Protection
Short Circuit, Phase Protection
Power Grid Voltage Phase Sequence and Frequency Self Adaptation
Overheat Protection
Open/Short Circuit Protection
Emergency Stop Protection
Voltage and Current Protection Value can be Set
Output Overvoltage/Overcurrent Protection
Channel Redundant Voltage Protection
DC Acute Reverse Connection Protection
Self-checking Protection
Equipment Power off Continuity Protection
Protection Log Traceability
Integrated Operation and Collaborative Work through BTS Upper Computer Control System
NEWARE battery charge and discharge test system realizes integrated operation and collaborative work through BTS upper computer control system, so as to maximize the battery characteristics and functions.
Peripheral Linkage
1BMS Protection Board Linkage
2Thermostat Linkage
3Water Cooling Machine Linkage
4Balance Equipment Linkage
Close to 100% Energy Recovery
Full Power Feedback Technology; Energy-feedback efficiency is more than 90%; Battery discharge energy is recycled and used for charging in other channels. If there is energy surplus, it will be fed back to the grid.
Size & Weight
① W*D*H : 600*800*1800(mm);Weight: 300kg。
② W*D*H : 600*800*1200(mm); Weight: 200kg。 a
② W*D*H : 600*800*1200(mm); Weight: 200kg。 a