CT-4000-5V0.6A/1A
0.05%FS accuracy and 3 RangeCT-4000-5V0.6A/1A
True Wireless Stereo (TWS) Testing
Pouch Cell(Polymer Clamps) | Bean Cell(Coin Cell/ Thimble Clamps)
  • 0.05%FS Accuracy
  • 3 Range (5V0.6A/1A)
  • Response Time≤2ms
  • Data Acquisition Frequency 10Hz
0.01% Accuracy, μA Current Unit,
Self transcendence, Reach 4 Range
  • 10Hz/ 100Hz
    Data Acquisition Frequency
  • 500ms
    Min. Pulse Width
  • Three-Electrode System
    Test
  • Charge & Discharge
    Rate
  • μA
    Current Unit
  • dQ/dV
    Curve
  • DCIR
  • 0.05%FS Accuracy
  • 3 Range
  • ≤500μs/1ms
    Response Time
10Hz/ 100Hz Data Acquisition Frequency
Sampling 10 or 100 data per second in a high speed, recording each voltage and current change accurately.
Pulse Width: 500ms
Talk about the concept of the three-Electrode System.
In the field of electrochemical research and battery testing, researchers (students) pay more attention to the potential difference between the working electrode (or auxiliary electrode) and the reference electrode while paying attention to the pressure difference between the working electrode and the auxiliary electrode. The auxiliary channel binding method is adopted to isolate from the main channel without interference, and the data is transmitted synchronously (sampling interval), so as to ensure the accuracy and consistency in the battery tests.
Via different current discharging, we can get the rate performance.
Testing with the μA current unit is more accurate and more convenient.
The design of the μA current unit plays a vital role in the field of current accurate measurement, which is more convenient and more accurate. Generally, magnetoelectric galvanometer can achieve μA level, electromagnetic galvanometer can achieve mA level. Sensitive galvanometer is used for students to check weak current or tiny voltage in DC circuit in the lab. It is a kind of high sensitive magnetoelectric instrument, which can measure the tiny current.
Big news! The latest version of Neware BTSDA is realeased with dQdV function.
dQ/dV Differential capacity curve: Where there is a peak on the curve meaning the charge and discharge curves have a voltage platform, and different peaks represent different electrochemical reactions.dQm/dV Differential specific capacity curve:dQ/Active material quality/dV.
DCIR=▲V/▲I=|V1-V2|/(I2-I1)
电池的内阻作为锂电池的关键特性之一,是影响锂电池功率性能和放电效率的重要因素, 是衡量锂电池功率性能和评估锂电池寿命的重要参数。测试方法,给电池施加一个短时电流脉冲,测量其端电压与开路电压的差。用这个差值除以测试电流即认为是电池的直流内阻。软件的设计支持不同的测试方法和不同数据取值方法,兼容性强,可根据需求进行设置计算。
come true 0.01% accuracy
Ultra-lightweight appearance, pro-inspired features, dQ/dV curve,multi-range,0.01% accuracy, and three-electrode system test.
To meet the various requirements adopted in advanced battery research, our equipments can automatically switch the current range in accordance with user settings to maintain consistent accuracy, and can be fitted with additional hardware to provide a number of optional features and capabilities.
Generally, the reaction time is divided into two parts: rise time (rise time ≤ 500 μ s) and fall time (fall time ≤ 500 μ s), and the sum of the two parts shall prevail.
Integrated operation and collaborative work through BTS upper computer control system
NEWARE battery charge and discharge test system realizes integrated operation and collaborative work through BTS upper computer control system, so as to maximize the battery characteristics and functions.
Software
Essential components
dQ/dV
Conditions Switches
Segment-Record Conditions
Control peripheral equipment by communication
Super-capacitor tesing
dQ/dV differential capacity curve: the peak on the curve indicates that there is a voltage plateau on the charge and discharge curve, and different peaks represent different electrochemical reactions.
Battery testing steps need to be estimated for several conditions according to different operations during testing applications; Conditions switches meet requirements for multi-exits programming types. “And””or” logic operation, “≥”, ”≤”, ”=” comparatively calculate; Time duration ”t”, can achieve control requirements for special testing. Every step supports 5 condition switches; Support multi-exits, go to any steps, achieve more flexible process control.
Data record settings for voltage, current and time are supported; 3 segment-record conditions can be set for each step; Every segment can be set: ΔT, ΔV and ΔI.
BTS Server come true the peripheral equipment (Battery tester & Automation) communication control via switch.
The unit of Q is Coulomb, 1 Coulomb = 1A * 1s = 1As; 1Ah = 3600 As(Amp Second); Work voltage U = Charge upper limited voltage - Discharge bottom limited voltage; Working voltage can be set and the EDLC coulomb could be calculated automatically by the software.
Size and Weight
Net weight of middle machine:2.5kg
Net weight of single equipment:About 5kg
They are TWS battery tester's excellent partner.