Size of Each Unit (W*D*H)(mm)606*800*1800(mm)
-
Weight200kg;
-
AC InputAC 220V +10% / -20%, 50Hz;
-
Input Impedance
Main Channel
≥1MΩ
Auxiliary Channel
≥400kΩ
-
Input Active Power8CH(5008):500W;80CH(5080):5000W
-
ResolutionAD:16bit;DA:16bit
-
Noise≤80dB
-
Voltage and Current SamplingFour Wire Connection
-
Types of Power DevicesMOSFET
-
Wiring Diagram of Input Power Supply
-
Voltage
Range:(0.3V+0.05Ω/m*Length (m)*Current (A)+0.05Ω*Current (A))~5V;(e.g. Testing Line Length: 2m,Current: 2A,Voltage Range: 0.6V~5V);
Testing/ Output Accuracy:± 0.02% of FS;
Resolution:16bit (0.08mV);
Stability:±0.25mV;
-
Current
Independent 3-Range: 15mA; 300mA; 6000mA;
Resolution:16bit (0.1mA);
Testing/ Output Accuracy:±0.04% of FS;
Stability: ±0.5mA @ 6000mA Range;
-
Power
Single Channel Maximum Output Power: 30W;
-
Auxiliary Voltage
Range: 0~5V;
Resolution: 16bit(0.08mV);
Accuracy: ±2.5mV;
-
Auxiliary Temperature
Range:-40℃~+85℃;
Resolution:0.1℃;
Accuracy:±(0.5 + 0.01 * |Th - Tc|)℃ Th - Testing Spot Temperature; Tc - Instrument Spot Temperature;
-
Charge/ Discharge
Charging& Discharging Mode: :Constant Current Charging / Constant Current/ Constant Voltage Charging / Resting / Constant Current Discharging / Constant Power Discharging / Constant Resistance Discharging / Constant Voltage Discharging
Independent Internal Resistance Testing Step;
Cut-off Conditions: Voltage, Current, Relative Time, Capacity, -ΔV;
-
Protect
Software Protection
Power down Data Protection;
Function of Offline Test;
The safety protection conditions can be set, and the setting specs include: upper voltage limit, lower voltage limit, upper current limit, lower current limit, upper capacity limit and delay time.
Hardware Protection
Hardware Anti-Reverse Connection Protection;
Channel Over-Current Fusing;
-
Channels per Cabinet80
-
Step Setting ModeSheet Editing
-
Data Record
Data Recording Conditions
Times △T:10ms~60000s;
Voltage △U:0.5mV~5000mV;
Current △I:1mA~6000mA;
Local Data Record Capacity
1GB/CH;
-
DatabaseMySQL
-
Data Output ModeExcel, Txt
-
Curve Type
Drawing Customized, 4 Y-Axes
-
Protection LevelIP20;
-
Temperature
Working Temperature Range: 25±5℃ (Accuracy Assurance), 25±20℃ (Extreme Working Temperature);
Storage Temperature Range: 0~50℃;
Temperature Drift: 50ppm;
-
Humidity
Relative Humidity Range of Working Environment: ≤70% RH (There is no condensation of moisture.)
Relative Humidity Range of Storage Environment: ≤80% RH (There is no condensation of moisture.)