Pack Energy-feedback charge and discharge battery testing system
CE-4000
  • Each Unit Size (W*D*H)(mm)
  • AC Input
    AC 380V ±10% / 50Hz
  • Input Active Power
    40000W
  • Resolution
    AD:16bit;DA:16bit
  • Input Impedance
    ≥100kΩ
  • Voltage

    Constant Voltage Range Control: 0.3V~60V;

    Minimum Discharge Voltage: 0V;

    Accuracy: ± 0.05% of FS;

    Stability: ± 0.05% of FS;

  • Current

    Output Range per Channel: 0.25A~50A;

    Accuracy: ± 0.05% of FS;

    Constant Voltage Cut-off Current: 0.1A;

    Stability: ± 0.05% of FS;

  • Power

    Single Channel Maximum Output Power: 3000W;

    Stability: ± 0.1% of FS;

  • Time

    Current Response Time (10%FS~90%FS)

    Maximum current rise time: 20ms;


    Step Time Range

    ① ≤(365*24) h/step; ②Time Format Support  00:00:00:00(h, min, s, ms)

  • Charge

    Charging Mode: Constant Current Charging, Constant Voltage Charging, Constant Current/ Constant Voltage Charging, Constant Power Charging;

    Cut-off Conditions: Main Channel (Voltage, Current, Relative Time, Capacity, -△V);


  • Discharge

    Discharge Mode: Constant Current Discharge, Constant Voltage Discharge, Constant Power Discharge and Constant Resistance Discharge;

    Cut-off Conditions: Main Channel (Voltage, Current, Relative Time, Capacity);

  • Energy Efficiency

    >85% (Comparied with Conventional Equipment)



  • Cycle Life

    Cycle Test Range: 1~65535次;

    Single Cycle Steps: 254;

    Loop nesting: it has the function of nested loop and supports up to 3 levels of nesting;

  • DCIR Test
    Support DCIR calculating with user defined point.
  • Protect

    Power down Data Protection;

    The safety protection conditions can be set, and the setting specs include: voltage upper limit, voltage lower limit, current upper limit, current lower limit and delay time;

    Function of Offline Test.

  • IP Protection Degree
    Protection Degree: IP20
  • Channel Characteristics
    Constant current and constant voltage adopt double closed loop structure.
  • Channel Control Mode
    Independent Control
  • Voltage and Current Sampling
    Four Wire Connection
  • Noise
    <85dB
  • Database
    Adopting MySQL database to centralized manage testing data.
  • Communication Mode of Upper Computer
    Based on TCP/ IP Protocol
  • Server Operating System
    Windows 7
  • Data Output Mode

    EXCEL 2003, 2010; 

    TXT.

  • Server Disk Configuration
    500GB
  • Communication Interface
    Network Interface
  • Leakage Current
    <5μA
  • Total Number of Channels
    8
  • Working Temperature Range
    0℃~40℃(Within the range of 25±10℃, accuracy drift is 0.005% of FS /℃)
  • Storage Temperature Range
    -10℃~50℃
  • Relative Humidity Range of Working Environment
    ≤70% RH(There is no condensation of moisture.)
  • Relative Humidity Range of Storage Environment
    ≤80% RH(There is no condensation of moisture.)
  • Auxiliary Channel (Optional)

    Type of Auxiliary Channel: Temperature and Voltage;

    Temperature Range: - 200℃ ~ 260 ℃ (Thermocouple);

    Temperature Accuracy: ± 1 ℃;

    Temperature Resolution: 0.1 ℃;

    Voltage Range: 0V ~ 5V;

    Voltage Accuracy: ± 0.1% of FS;

  • Number of Temperature Auxiliary Channels per Channel (Optional)
    Up to 248 Temperature Auxiliary Channels.
  • Number of Auxiliary Channels with Voltage per Channel (Optional)
    Up to 248 Voltage Auxiliary Channels
  • Auxiliary Channel Protection Conditions

    Auxiliary Channel Protection Conditions can be Set, and the settable Specs include: Temperature Upper Limit, Temperature Lower Limit, Voltage Upper Limit, Voltage Lower Limit and Cell Differential Pressure.

Neware and Cookies
This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies.Read our private policy